Surgical spray foam removal & roof ventilation reinstatement
Carefully peeling or dry-ice blasting closed-cell or open-cell polyurethane foam from roof rafters, timber moisture testing, replacing decayed rafters/battens, and restoring eaves-to-ridge cross ventilation.
It works when the diagnosis is right and the wall is the type the repair was made for. Misapplied, it wastes money or moves the water.
When it works
Mortgage lenders have flagged spray foam on pitched roof rafters, or where high timber moisture content (concern above about 20% WME under BS 5250 fungal-risk logic) and decay are detected behind the foam. Timber rafters are structurally inspected and sound rafter cross-sections are certified by an independent surveyor.
When it fails or causes harm
Contractors hack away at foam with uncontrolled reciprocating saws, slicing into historic rafter edges or piercing unreinforced bitumen slaters' felt. Also fails if roof ventilation is not restored, as moisture will continue to condense in the unvented loft.
Frequently asked
What does surgical spray-foam removal and ventilation reinstatement involve?
Controlled removal (peel / dry-ice blast — not reciprocating saws into rafter edges or bitumen felt), moisture testing of rafters (concern above ~20% WME), replacement of decayed timber, and reinstatement of eaves-to-ridge cross ventilation so the cold roof can dry (BS 5250; PCA spray-foam guidance; Approved Document C moisture logic). Lenders often require specialist reporting before retention release. Certify remaining section, restore soffit/ridge paths, and refuse ‘open-cell top-up’ over a still-unvented cold roof. Hacking foam off without ventilation leaves the condensation mechanism intact.