Guides
Guides
Step-by-step procedures for damp investigation, fire-door checks, loft and subfloor airflow, AST repair clauses, planning applications, and BIM workflows.
How to use this section. Guides are arranged by subject — damp investigation, fire doors, loft and subfloor airflow, AST clauses, planning applications, BIM workflows, and more.
UK & Ireland
Investigate a damp wall before anyone treats it
The order a careful survey uses. Name the construction, separate the patterns, and only then look at a remedy. A moisture meter is not step one.
UK & Ireland
A single-storey extension in England
Planning, the Building Regulations 2010 (as amended) / Approved Documents, and the junction with the house you already have. The junction is where the next damp problem and the next crack are made. The figures below were checked against Class A of the GPDO as published in 2026. They are not a decision on your house.
UK & Ireland
Pre-2000 domestic refurbishment & asbestos management (HSG 264)
What homeowners, surveyors, and builders must check before knocking down walls, replacing soffits, or disturbing Artex in pre-2000 homes. Survey types, sampling protocols, and legal responsibilities under the Control of Asbestos Regulations 2012.
UK & Ireland
Internal wall insulation (IWI) on solid masonry: breathable woodfibre vs PIR
Why retrofitting internal insulation on solid brick or stone can cause joist-end rot and hidden interstitial damp. The building physics of vapour permeability, capillary activity, and why breathable woodfibre outperforms foil-faced PIR.
UK & Ireland
Commissioning Heritage BIM (H-BIM) for a historic building
How to specify and commission a non-destructive Heritage BIM survey for pre-1919 / Georgian–Victorian solid fabric and listed buildings: point cloud LiDAR, photogrammetry, non-contact movement monitoring, and AR/VR digital conservation without damaging delicate historic fabric.
UK & Ireland
Setting up an ISO 19650 BIM information workflow
From client brief to operational digital twin: defining OIR, PIR, AIR, and EIR, evaluating the pre-appointment BEP, managing the CDE, and avoiding the 'dug foundations' trap.
UK & Ireland
Surveying and certifying a timber fire door (FD30S / FD60S)
The complete surveyor inspection protocol for high-risk residential blocks and student accommodation: component checklist, catching twisted frames, managing the 3-year failure rate curve, and ensuring compliant carpentry re-inspection.
Southeast Asia
A damp ground floor in a Thai concrete-frame house
Do not import a British rising-damp certificate. Read the frame, follow the monsoon down the outside, then look at the air-conditioning. Most of what gets called damp here is rain, splash, a drip, or condensation.
Southeast Asia
Foundations, driven micropiles and settlement joints in Central Thailand (Bangkok clay)
Why shallow footings sink in soft Chao Phraya marine clay, how driven prestressed concrete micropiles reach the 18m–21m stiff bearing layer, and the essential 25mm structural movement joint separating extensions from the main house.
UK & Ireland
Choosing a retrospective BIM tier with residents before scanning
A managing-agent walkthrough: table Tier 1 plans, Tier 2 fire mapping, Tier 3 AIM/COBie, and optional Tier 4 twin with leaseholders — agree the stopping tier and priced exclusions before any laser scan, under Landlord and Tenant Act 1985 reasonableness and Building Safety Act information duties.
UK & Ireland
Prepare a householder planning application in England
A homeowner and agent sequence: confirm England, test permitted development, then assemble drawings, certificates, and statements for validation — without confusing planning with Building Regulations.
UK & Ireland
Investigate upper-floor damp through the loft
First-contact order for mould or alleged roof leaks under a cold pitched roof: map where airflow currently operates; only if the loft can still breathe, turn to water ingress through the underlay. Then name covering-versus-membrane roles, missing tiles, token vent cuts, extract ducts, and lifestyle. Airflow needs an entry and an exit.
UK & Ireland
Investigate ground-floor damp through underfloor airflow
First-contact order for low damp on suspended timber floors: name the construction, map designed opposite air bricks, find what landscaping or extensions blocked them, restore through-flow, then expand to drains, bridging, and true rising damp only if the void already breathes.
UK & Ireland
Standard AST agreements: plain-English repair clauses & statutory limits
Cross-reference the five dominant UK Assured Shorthold Tenancy template families (Gov Model, NRLA, OpenRent, Propertymark/ARLA, DIY) against Landlord and Tenant Act 1985 s11, Fitness 2018 / s9A, HHSRS, and Consumer Rights Act 2015 s62 — so contractual repair wording is read against the statutory floor.
UK & Ireland
Loft conversion pathology in England
How loft conversions create moisture, structure, fire, and weatherproofing defects — and the order to investigate before blaming ‘the roof’.
UK & Ireland
Party walls in England — process and common failures
Plain-English map of the Party Wall etc. Act 1996 process and the building defects that often sit beside disputes — not a substitute for appointing a party wall surveyor.
UK & Ireland
New-build warranties and the defects period
How NHBC-style warranties, developer defects periods, and Building Regulations completion interact — and how to investigate snags without losing the mechanism.
UK & Ireland
Flood recovery and drying — fabric first
After clean or contaminated flood water: strip, dry, and verify moisture before reinstatement — so mould and trapped wet insulation are not built back in.
UK & Ireland
Moisture survey methods — meters, sampling, and imaging
What conductance meters, carbide/gravimetric sampling, and thermal imaging can and cannot prove — so agents and owners are not sold a diagnosis from a single beep.
UK & Ireland
Garage conversion pathology in England
How converting a garage into a room creates moisture, thermal, fire, and structure defects — and the order to check before decorating the new ‘bedroom’.
UK & Ireland
Knocking through and steels — load paths before the open-plan look
Removing walls for open-plan living: how to think about load-bearing walls, beams, padstones, and the cracks that follow bad steels — without replacing an engineer.
UK & Ireland
Permitted development traps for householders in England
Where householder permitted development is misunderstood — Article 4, prior approval, height/depth limits, and the myth that PD skips Building Regulations.
UK & Ireland
Roof underlays — bitumen felt vs breathable membranes
How underlays manage water and vapour in pitched roofs — and why swapping felt for a membrane (or sealing a cold roof) changes condensation risk.
UK & Ireland
CDM roles on small residential projects (England / GB)
Client, principal designer, and principal contractor duties under CDM 2015 on domestic extensions and refurbishments — plain English, not a substitute for HSE advice on a live project.
UK & Ireland
Radon in UK dwellings — test, protect, do not guess
What radon is, when to test, how Building Regulations address new work in affected areas, and why radon is not cured by a damp-proof injection.
UK & Ireland
Drain CCTV and underground drainage investigation
When to camera the drains, what CCTV can and cannot prove, and how underground failures present as ‘damp’ or garden sinkholes.
UK & Ireland
Crack monitoring methods — when to watch and when to call an engineer
Tell-tales, gauges, photos, and level surveys: how to evidence whether cracks are live — and when monitoring is delay dressed as diligence.
UK & Ireland
Lead paint in older dwellings — disturb carefully
Where lead-based paints remain in pre-1970s UK stock, how refurbishment creates exposure risk, and why this sits beside asbestos and CDM planning — not a damp diagnosis.
UK & Ireland
PIR vs woodfibre insulation — mechanism, not a shopping list
How rigid PIR/phenolic boards and woodfibre (or other vapour-open) insulations change heat, vapour, and fire behaviour — so retrofit choices follow the wall, not the brochure.
UK & Ireland
Insurance-backed guarantees vs evidence-graded remedies
What a contractor ‘guarantee’ or insurance-backed warranty usually covers — and why it is not the same as a correct moisture or structure diagnosis.
Southeast Asia
Singapore facade moisture — BCA context for agents
How monsoon rain, AC-driven reverse vapour, and facade maintenance meet Singapore Building and Construction Authority expectations — without exporting England DPC theatre.
Hot-arid / desert
Gulf AC condensation — cold surfaces in humid seasons
How aggressive air-conditioning on heavy or lightweight Gulf dwellings creates surface and condensation inside the wall or roof layers (interstitial condensation) when outdoor humidity spikes — mechanism first, product second.
UK & Ireland
Condensation risk analysis — Glaser vs how heat and moisture move through the wall
When steady-state Glaser checks are enough, when BS EN 15026 dynamic simulation is warranted, and how both still sit under BS 5250 field judgement.
UK & Ireland
EPC myths vs fabric-first retrofit
What an Energy Performance Certificate can and cannot tell you — and why chasing a rating without moisture logic creates mouldy ‘improvements’.
UK & Ireland
PAS 2035 whole-dwelling retrofit process
How PAS 2035 structures risk assessment, retrofit coordination, and sequencing — so energy upgrades do not ignore moisture and ventilation.
UK & Ireland
Scaffolding and temporary works — liability in plain English
Who typically owns design, inspection, and public protection for scaffolds and temporary works — orientation for clients and agents, not a design manual.
Southeast Asia
Malaysia facade moisture — UBBL orientation
How monsoon rain, AC-cooled interiors, and Malaysian Uniform Building By-Laws context meet facade building defects — without exporting England DPC kits.