PAS 2035 whole-dwelling retrofit process

How PAS 2035 structures risk assessment, retrofit coordination, and sequencing — so energy upgrades do not ignore moisture and ventilation.

  1. 1

    Whole dwelling, not a single measure

    PAS 2035 expects assessment of the house as a system: fabric, ventilation, heating, occupancy, and heritage constraints — not isolated grant measures.

  2. 2

    Roles and competence

    Retrofit assessor / coordinator pathways exist so someone owns risk and sequencing. DIY measure-stacking without that role recreates known failures.

  3. 3

    Moisture and ventilation are in scope

    BS 5250 condensation logic and extract performance sit inside responsible retrofit — not optional extras after the insulation invoice.

  4. 4

    Traditional buildings need extra care

    Historic England and Joint Position Statement thinking still apply on solid-wall stock. PAS 2035 does not licence impermeable finishes on wet lime walls.

  5. 5

    Handover and monitoring

    Occupant guidance and post-works checks catch blocked vents and misused MVHR filters before mould returns.