Skip to content

Guide · UK & Ireland

Knocking through and steels — load paths before the open-plan look

Removing walls for open-plan living: how to think about load-bearing walls, beams, padstones, and the cracks that follow bad steels — without replacing an engineer.

  1. 1

    Decide if the wall is load-bearing

    Not every partition carries floors or roofs, but many ‘non-load-bearing’ claims are wrong. Look at joist direction, wall thickness, stack alignment, and whether the wall continues above. When unsure, instruct a structural engineer before demolition.

  2. 2

    Temporary works and sequence

    Needles, props, and a designed sequence protect the floors above. Knocking a hole and hoping the steel ‘will fit later’ is how ceilings drop and party walls crack.

  3. 3

    Beam, bearings, and padstones

    A correctly sized steel still fails if bearings are short, padstones missing, or loads concentrate into weak masonry (Approved Document A territory). Flange packing and fire protection are part of the detail, not extras.

  4. 4

    Read the cracks after the works

    Diagonal cracks from bearings, distorted door heads, and stepped cracks above openings often mean movement at the new opening — not ‘settlement of an old house’ as a first story. Monitor and involve the engineer who designed the beam.

  5. 5

    Party wall and building control

    Shared walls and nearby excavations can trigger the Party Wall etc. Act 1996. Structural alteration needs Building Regulations. Open-plan aspiration does not waive either track.