Moisture tools
Is the loft breathing?
First contact for upstairs mould or an alleged roof leak: where does loft air enter and leave? Packed soffits mean airflow is cut off — treat that before ingress. Only when the loft can breathe turn to underlay defects, missing tiles that expose a membrane problem, and token vent cuts. Answer yes / no / not sure through the checklist.
1.Eaves / soffit / tile vents presentCritical
For this cold pitched roof, are soffit vents, eaves slots, fascia vents, or tile/ridge vents present as the designed intake and exhaust?
Cold roofs rely on a deliberate ventilation path. Without vents (or a vapour-open underlay system that truly replaces them), moist air that reaches the loft has nowhere useful to go — BS 5250 / NHBC 7.2.15.
2.Insulation clear of eaves pathCritical
Is loft insulation kept clear of the eaves / soffit ventilation path — not packed over or stuffed into the vents (including after a later loft-insulation retrofit)?
Classic defect at handover and after energy retrofits: quilt pushed into the eaves, blocking the only airway on a house that may have been dry for years. Moisture then tracks into upper walls (loft sweating). NHBC expects spacers/baffles so insulation covers the wall plate without blocking the path or rolling back.
3.Entry and exit airflowCritical
Can air enter on one side of the roof and leave on another (opposite eaves, or eaves plus ridge/high-level vents) so the loft has a through path — not only token vents on one slope?
Ventilation is airflow. One opening without an exit is inefficient; opposite eaves (or eaves-to-ridge) create the wind path that removes moisture. One or two tile vents on the same slope look like compliance while the loft stagnates — especially once underlay made the void airtight.
4.Tile / ridge vent detailing
Where tile or ridge vents pierce the underlay, are they proprietary sealed details — and not raw cuts that add rain ingress under a tile-over-membrane roof?
Modern coverings often protect a waterproof underlay rather than acting as the sole rain barrier. Cutting that membrane for a vent without a sealed unit creates an ingress point. Token vents can therefore add leak risk without delivering through-flow.
5.Wet-room extract to outsideCritical
Do bathroom and kitchen extracts discharge to outside air — not dumping into the loft void?
A duct that ends in the loft adds litres of water vapour a day into the cold space. That is a construction / installation error, not a lifestyle quirk — BS 5250; Approved Document F.
6.Ceiling / hatch vapour control
Are the loft hatch, pipe penetrations, and ceiling openings reasonably sealed so warm moist room air is not freely dumped into the cold loft?
Even with clear eaves, an unsealed hatch left open and gaps around downlights or pipes drive condensation inside the wall or roof layers (interstitial condensation) on cold underlay. Seal the warm side; ventilate the cold side.
7.Underlay / membrane intact
Is the roof underlay / membrane free of construction punctures, open laps, or unsealed vent cuts above the affected ceiling or bedroom?
A hole — including from a re-roof or tile vent — can wet insulation repeatedly for years before a stain finally presents downstairs. On tile-over-membrane roofs the covering is not the sole waterproofing; breaches of the underlay matter. Early wetting can dry between storms; cumulative saturation shows as ‘new’ damp that is an old defect.
8.Missing tile → membrane inspected
If tiles or slates are missing or displaced above the damp, has the underlay beneath been inspected from the loft — rather than blaming the missing covering alone for indoor wetting?
On modern tile-over-membrane roofs the covering protects the waterproof underlay. A missing tile raises membrane risk and should be replaced, but indoor damp usually means a pre-existing underlay defect that the gap exposed. Closing the case at ‘tile missing’ skips the real path.
9.Working wet-room extract
Is wet-room extract working, powerful enough for the room, and used during and after showers / cooking (Approved Document F practice)?
Surface condensation and mould in bathrooms and bedrooms often starts as vapour the extract never removed. Lifestyle and undersized fans both matter once the roof void is cleared.
10.Winter background / purge air
In winter, are trickle vents left open (or equivalent background ventilation used), with occasional purge ventilation, rather than sealing every opening to keep heat in?
Shutting windows, trickle vents, and doors traps moisture. Without an indoor path in and an outdoor path out, vapour settles on cold surfaces — NHBC roof-space advice and Approved Document F background ventilation.
Result
No answers yet
First-contact order: map where loft airflow operates now. If soffits are packed or there is no through-path, lead with airflow. Only when the loft can breathe turn to underlay ingress, missing tiles, and vent cuts.
Confirmed yes: 0 · No: 0 · Not sure: 10
What this reading suggests
Start with airflow (vents present, eaves clear, cross-ventilation), then tile-vent detailing, outdoor extract, ceiling seals, underlay, missing-tile membrane checks, wet-room extract, and winter background vents. Re-run the triage once those are answered.
- Eaves / soffit / tile vents presentunknown · unknown
Not confirmed yet. Ask: For this cold pitched roof, are soffit vents, eaves slots, fascia vents, or tile/ridge vents present as the designed intake and exhaust?
Related guidance → - Insulation clear of eaves pathunknown · unknown
Not confirmed yet. Ask: Is loft insulation kept clear of the eaves / soffit ventilation path — not packed over or stuffed into the vents (including after a later loft-insulation retrofit)?
Related guidance → - Entry and exit airflowunknown · unknown
Not confirmed yet. Ask: Can air enter on one side of the roof and leave on another (opposite eaves, or eaves plus ridge/high-level vents) so the loft has a through path — not only token vents on one slope?
Related guidance → - Tile / ridge vent detailingunknown · unknown
Not confirmed yet. Ask: Where tile or ridge vents pierce the underlay, are they proprietary sealed details — and not raw cuts that add rain ingress under a tile-over-membrane roof?
Related guidance → - Wet-room extract to outsideunknown · unknown
Not confirmed yet. Ask: Do bathroom and kitchen extracts discharge to outside air — not dumping into the loft void?
Related guidance → - Ceiling / hatch vapour controlunknown · unknown
Not confirmed yet. Ask: Are the loft hatch, pipe penetrations, and ceiling openings reasonably sealed so warm moist room air is not freely dumped into the cold loft?
Related guidance → - Underlay / membrane intactunknown · unknown
Not confirmed yet. Ask: Is the roof underlay / membrane free of construction punctures, open laps, or unsealed vent cuts above the affected ceiling or bedroom?
Related guidance → - Missing tile → membrane inspectedunknown · unknown
Not confirmed yet. Ask: If tiles or slates are missing or displaced above the damp, has the underlay beneath been inspected from the loft — rather than blaming the missing covering alone for indoor wetting?
Related guidance → - Working wet-room extractunknown · unknown
Not confirmed yet. Ask: Is wet-room extract working, powerful enough for the room, and used during and after showers / cooking (Approved Document F practice)?
Related guidance → - Winter background / purge airunknown · unknown
Not confirmed yet. Ask: In winter, are trickle vents left open (or equivalent background ventilation used), with occasional purge ventilation, rather than sealing every opening to keep heat in?
Related guidance →
Field triage against BS 5250 cold-roof practice and Approved Document F — not a substitute for a Chartered Building Surveyor’s investigation, opening-up, or rainwater / plumbing proof.
Frequently asked
At first contact for upstairs mould or an alleged roof leak, what should be checked before blaming water ingress?
Where loft airflow enters and leaves. Packed soffit vents or no through-path are enough to lead with loft sweating / condensation inside the wall or roof layers (interstitial condensation) (BS 5250; NHBC 7.2.15). Fail eaves-path-clear or cross-ventilation on the triage and restore clear eaves/baffles (/remedies/clear-eaves-loft-ventilation) before diagnosing liquid leaks, missing tiles, or a full re-roof. Only when airflow is adequate turn the investigation to the underlay.
Is loft insulation packed over soffit or eaves vents on a cold pitched roof?
If yes, treat that as the primary mechanism for many upper-bedroom damp presentations — including after a later loft-insulation retrofit on a previously dry house. Cold roofs need a clear eaves path (BS 5250; NHBC 7.2.15 spacers/baffles so quilt covers the wall plate without blocking airways or rolling back). Prefer soffit/eaves vents when the building allows — lower ingress risk than cutting the underlay. Mark eaves-path-clear and cross-ventilation ‘no’; do not sell a chemical DPC or default full re-roof while the loft cannot breathe.
On a modern underlay roof, does a missing tile prove the house is taking water through that gap?
No — not by itself. Tiles often protect a waterproof membrane that should still drain ordinary rain to the gutter (BS 5250). Replace the tile to protect the membrane, but indoor damp usually means a pre-existing underlay defect the gap exposed (poor laps, tears, unsealed vent cuts). Fail missing-tile-membrane-checked if the underlay was never inspected from the loft; name covering-only versus membrane-drained generation before closing the case.
Do one or two tile vents on the same slope, or unsealed underlay cuts at vents, explain damp that others called a whole-roof failure?
Often yes. Token single-slope vents fail entry-and-exit airflow while piercing the waterproof underlay (BS 5250; NHBC pitched-roof ventilation) — like a hole in a waterproof coat. Slow saturation can take years to show through insulation and plasterboard. Fail cross-ventilation and/or tile-vent-detail-sound; prefer sealed opposite groups or eaves-to-eaves over wholesale re-cover. Open /guides/loft-ventilation-upper-floor-damp.
If the loft airways look clear, why might mould still form when trickle vents stay shut all winter?
Dwelling moisture still needs an indoor path out. Sealed winter living traps vapour on cold surfaces even when the loft breathes (NHBC roof-space advice; Approved Document F background and purge). Pass critical eaves items only when evidenced; if wet-room extract or winter-background-ventilation is ‘no’, report a dwelling-ventilation gap, advise extract use and open trickle vents, and keep /defects/surface-condensation in play.
Related reading: loft inspection guide, clear eaves ventilation, cold pitched roofs, interstitial condensation, dew point calculator.