Defect · moisture
Conservatory and orangery thermal-break failures
Condensation, mould, and cold floors where lightweight glazed rooms meet the heated house without adequate thermal breaks, drainage, and vapour control.
Mechanism
Conservatories and orangeries are often thermally weak boxes bolted to a warmer dwelling. Without continuous insulation, thermally broken thresholds, and controlled openings to the house, cold surfaces fall below dew point (BS 5250). Leaking roofs and perimeter drains add rain. Opening the house permanently to the conservatory without upgrading fabric creates a condensation machine in winter.
Often confused with
- Rising damp from the main house DPC
- Only a roof leak with warm, dry frames
- Lifestyle mould with no cold-surface evidence
What would support it
- Mould/condensation on frames, ceilings, or the house junction in cold weather
- Missing thermal breaks, single glazing, or uninsulated dwarf walls
- Wet perimeter after rain at the conservatory roof/wall junction
What would rule it out
- Dry, warm conservatory with a clear plumbing leak in the house only
- Rain stains with no cold-weather pattern and proven membrane breach only
Common mistakes to avoid
- Do not permanently open the house without upgrading the conservatory fabric
- Do not ignore gutter and perimeter drainage around the add-on
- Do not treat frame condensation with rising-damp injection
Frequently asked
Why is the conservatory dripping when the house is fine?
Because lightweight glazed rooms cool fast and often lack thermal breaks at floors and junctions, so indoor vapour hits dew point on cold surfaces (BS 5250; Approved Document L/F thinking). Measure surface temperatures, check whether the house is permanently open to the conservatory, and fix rain on the add-on roof separately from condensation.
Remedies
- EstablishedExtract the moisture where it is made
Take water vapour out of kitchens and bathrooms at source, and give the rest of the dwelling background and purge ventilation, as Approved Document F describes.
- EstablishedSteady heat and fewer cold surfaces
Surface condensation forms where room air meets a surface below the dew point. Steady low heat, and dealing with the cold bridge, removes the condition. Intermittent blasts of heat do not.
A large share of damp sold as a wall problem is a rainwater fitting that does not carry water away. Repair the path before treating the wall.
- ConditionalRepair a broken vapour-control layer
Warm moist air that gets into a cold frame or a cold roof condenses there. The repair is continuity of the vapour-control layer, and often less insulation stuffed into a vent path. It is conditional on the build-up actually being a cold-side condensation problem.