Defect · moisture
Hygroscopic salts (salts that draw damp from the air)
Salts already in the plaster or masonry pull moisture out of humid air. The patch returns in muggy weather even when the leak or the ground water has stopped.
Mechanism
Chlorides and nitrates from ground water, and salts from long use of a flue, are hygroscopic. Sulfates more often appear as fluffy crystals as water evaporates. A salt-contaminated patch has a sharp edge, often a single area of chimney breast or the ghost of an old tide mark. Electrical meters scream. The masonry behind can be at a normal moisture content. Painting it seals the salts in until they blow the paint off.
Often confused with
- Active rising damp, which has a moisture gradient in the wall, not only salts in the plaster
- Condensation, which prefers cold surfaces and grows mould rather than a crust
- A live chimney or roof leak at the same breast
What would support it
- The patch fades in a dry spell and returns when the air is humid, without rain
- It sits on a chimney breast, or in the footprint of an old damp band
- A hygroscopic moisture test on samples distinguishes salt-held water from free water
What would rule it out
- Samples from the wall are wet in depth, wetter at the base, and a source of water is still active
- The stain grows down from a ceiling or out from a pipe fitting
Common mistakes to avoid
- Do not inject a damp-proof course for a salty chimney breast
- Do not keep repainting with a waterproof coating
- Do not assume salts mean the ground water is still rising
Frequently asked
Why does a handheld moisture meter read high on a dry-looking chimney breast?
Conductance meters respond to ions. Hygroscopic flue salts (and residual ground salts) raise conductivity even when free water in the masonry is low, so the pin or pad screams on a visually dry breast. BRE Digest 245 states a high meter reading is not, on its own, rising damp. Separate free moisture from hygroscopic moisture on oven-dried drilled samples; if the wall body is at a normal moisture content and the plaster alone holds the salts, the 'damp' is salt behaviour in humid air, not an active ground feed. Do not sell a chemical DPC from a chimney-breast meter reading. Replace contaminated plaster after the moisture source — if any — is stopped.
What does a low-level salt band (tide mark) actually prove — and what does it not prove?
A tide mark proves salts have been deposited where moisture evaporated — often chlorides and nitrates from historic ground moisture, or mixed salts from an old episode. It does not prove water is still rising today. Hygroscopic residues keep the plaster looking damp whenever room humidity rises, long after the source stopped. Digest 245 / BS 6576 want gradient evidence of free water in the wall body and chemistry that fits an active source before you name live rising damp. Photograph the band, sample for free vs hygroscopic moisture, and hunt for bridging or rain paths. A painted-over tide mark that returns every muggy week is salts until the samples say otherwise.
Are chlorides and nitrates from a flue the same as rising-damp ground salts?
They are chemically overlapping families but different stories. Ground moisture classically carries chlorides and nitrates into the base of the wall; combustion and long flue use load chimney breasts with chlorides and other combustion residues high up the stack. Location is the first discriminator: mid-height or first-floor breast salts are flue history until a continuous masonry path from wet ground is proved. Sulfates more often show as fluffy efflorescence from evaporating water or gypsum residues and are a weak rising-damp signature on their own. BRE Digest 245 / BS 6576 still want height profiles and free-moisture evidence before any chloride package is sold as live rising damp. Map height and construction, then laboratory salt typing — do not inject the breast because the flue once ran coal.
Why does a salt-contaminated patch look damp in humid weather and fade when the air is dry?
Hygroscopic salts (salts that draw damp from the air) take up vapour from humid air until a film of water sits on the plaster surface; when RH drops, that film evaporates and the patch looks dry again. No new leak is required. That cyclic behaviour, sharp edges, and a screaming meter with a dry core are the textbook hygroscopic pattern under Digest 245 sampling logic. Condensation prefers cold surfaces and grows mould; salt patches crust and stain without needing dew-point contact every time. Log weather and RH against the patch, then test samples. Repainting with waterproof coatings traps the salts and blows the next decorate — remove contaminated plaster after the source is dead.
What salt analysis (chloride / nitrate / sulphate) separates rising damp, flue salts, and penetrating damp?
Use chemistry with location and free-moisture profile, not as a lone oracle. Elevated chlorides and nitrates at the base of a ground-storey masonry wall with a decreasing free-moisture gradient support historic or live ground moisture (Digest 245 / BS 6576). The same ions high on a chimney breast without a ground path point to flue residues. Sulfates alone more often track evaporation, gypsum plaster, or some penetrating/evaporative cycles and do not confirm rising damp. Penetrating rain can move salts around but usually lacks the classic low-band chloride/nitrate package unless it remobilises old ground salts. Commission quantitative salt tests with height profiles; refuse a DPC quote that cites only 'salts present' without free-water evidence and a mechanism that fits the wall.
Remedies
- ConditionalReplace salt-contaminated plaster
Ground salts and flue salts stay in the plaster after the water has stopped. They pull moisture from humid air and destroy decorations. After the wetting mechanism is named, contaminated plaster has to come off; on pre-1919 lime fabric prefer breathable lime / renovation plasters — dense cement ‘salt-holding’ systems are not the default first action on traditional walls.
- EstablishedFind and repair the leak
Plumbing, roofs, flat roofs, and condensate pipes produce stains that look like 'damp'. The repair is the pipe, the covering, the outlet, or the flashing. Drying comes after the water has stopped.